StorEdge 3310 - mpxio/traffic manager possible?

2007-12-25 3:15:00

Greetings,

We have a V240 with
Solaris 8
StorEdge PCI Dual Ultra3 SCSI Host Adapter, X6758A
connecting to a
StorEdge 3310 with dual scsi controller

and am wanting to use multipathing.

I've configured the SE3310 so that it presents the same volumes via multiple scsi id's

AVAILABLE DISK SELECTIONS:
0. c1t0d0 <SUN36G cyl 24620 alt 2 hd 27 sec 107> Root
/pci at 1f,700000/scsi at 2/sd at 0,0
1. c1t1d0 <SUN36G cyl 24620 alt 2 hd 27 sec 107> intrn1
/pci at 1f,700000/scsi at 2/sd at 1,0
2. c1t2d0 <SUN36G cyl 24620 alt 2 hd 27 sec 107> intrn2
/pci at 1f,700000/scsi at 2/sd at 2,0
3. c1t3d0 <SUN36G cyl 24620 alt 2 hd 27 sec 107> intrn3
/pci at 1f,700000/scsi at 2/sd at 3,0
4. c5t0d0 <SUN-StorEdge3310-0325 cyl 44281 alt 2 hd 127 sec 127> 3310vol1
/pci at 1d,700000/pci at 2/scsi at 4/sd at 0,0
5. c5t1d0 <SUN-StorEdge3310-0325 cyl 44281 alt 2 hd 127 sec 127> 3310vol2
/pci at 1d,700000/pci at 2/scsi at 4/sd at 1,0
6. c6t0d0 <SUN-StorEdge3310-0325 cyl 44281 alt 2 hd 127 sec 127> 3310vol2
/pci at 1d,700000/pci at 2/scsi at 5/sd at 0,0
7. c6t1d0 <SUN-StorEdge3310-0325 cyl 44281 alt 2 hd 127 sec 127> 3310vol1
/pci at 1d,700000/pci at 2/scsi at 5/sd at 1,0

The docs talk about VERITAS Dynamic Multi-Pathing (DMP) but for cost reasons I'm
not eager to buy DMP.

Is it possible to do Multi-Pathing using Sun Storage Traffic Manager Software (MPXIO)

The SE3510 works with mpxio but costs more.

Thanks

Alberto da Silva