Urgent problem with U60 Clone

2007-12-25 10:30:00

****** Message from InterScan E-Mail VirusWall NT ******

** No virus found in attached file noname.htm

***************** End of message ***************


Thanks a lot for all the fast replies to my post. Sadly, they didn't

help us solving the problem. Of the two broken machines, one booted

again after dozens of power-down/power-up cycles. Since then it has

been running fine for four days now. The other machine is currently on

the way to our supplier for repair.

I should have stated more clearly in my original post that both

machines were in operation before. The problem occured after powering

them down due to an exchange of a UPS.

All replies suggesed that we probably have some sort of hardware problem.

Someone mentioned seeing these messages with improperly inserted memory

chips and also with incorrect pin-outs on a terminal connection to the

console port. This is not the case here, the message is also displayed

without memory installed and the terminal works fine.

Others suggested trying the various test commands in OBP. We did that

before posting, but were not able to use them to localize the problem.

with 'diag-switch? true' the machine would either stop at the floppy

test with a watchdog reset or go in an endless loop displaying a

register dump and starting the test all over again. We also reset the

OBP values to default (even if we didn't change them), but that also

did not help.

If I will ever find out the real reason for the problem, I'll post a

second summary.

Jan-Olaf

The original question was:

Dear Sun-Managers,

we've got two Ultra 60 clones (but with the original SUN motherboard),

which won't boot anymore.

All they say is

        Watchdog Reset

        Externally Initiated Reset

and display the OBP ok prompt. This happens both when powering them on

an when entering `reset' at the ok prompt. After that, there are no

SCSI-controllers found (tried probe-scsi and test scsi), so it won't boot.

Does anyone have an idea what could be the reason for this message?

Any piece of hardware we could try to change? I've already exchanged the

CPU modules, but this doesn't help. Since here are public holidays today,

I can't ask our supplier.


--
Jan-Olaf Droese | Lahmeyer International GmbH
email: zdjod@lif.de | Friedberger Straße 173
phone: +49-6101-55-1611 | 61118 Bad Vilbel
fax: +49-6101-55-1623 | Germany

Comments

Got something to say?

You must be logged in to post a comment.