SUMMARY: replacing serial terminal
2007-12-24 23:33:00
Tony Walsh
Olaf Hopp
and Steven Haywood (his statement is listed below...)
Just turn the keyswitch (if it has one) to the secure position
Or
type kbd -a disable from a root prompt :)
Both stop the break signal from dropping to rom mode
Cheers
Steven
----------------------------------------------------------------------------
-------------
I wrote:
Hi everybody
I'm about to change a serial terminal on a e4000 (running Sol. 2.5.1).
Many people told me that if I plug in the new terminal it'll produce a
<break> wich will, obviously, stop the server.
I can login via telnet or rlogin ant any time. So, maybe swaping the ttya
<-> ttyb and then plugin the terminal would do.
Might this work ? and if, how to swap the tty's ?
cu
may