Problems in dialing

2007-12-25 8:10:00

Well, not much of a summary, as I got just one answer, from

 tellab5!vpnet!trdlnk!mike@uunet.UU.NET .

My problems with a 2400/MNP modem on a SparcStation 10 with SunOs 4.1.3

were the following:

% If I use a tcsh, I seem to have a parity error (not present in csh and sh);

% and what is worse, just a simple ls starts well but got scrambled in the way,

% as if there would be no flow control.

the answer to the first problem remains unknown, while for the second one

% Your flow (not "flux") control problem can probably be fixed by adding crtscts

% to the ms capability of the /etc/gettytab entry thus:

%

% P|8bit.9600|9600-baud-8bit|8bit:\

% :sp#9600:p8:ms=crtscts:

%