SCSI transport failed

2007-12-25 11:43:00

Hello Sun Managers,

Here is my original post:

> I have a Sparc 1 4/60 running SunOS 4.1.4 that has taken a severe

> performance hit,

> by this I mean everything is slow- disk I/O, network response time, a

> simple df takes

> 9 seconds as opposed to 2 seconds on a similar machine. We have not

> made any

> recent hardware or software changes, additions,... and it had been

> stable for

> several months prior to this incident.

>

> I have used standard utils to try to identify the cause ( e.g. top,

> iostat, vmstat,...)

> but with no luck.

>

> I did find the following errors in /var/adm/messages:

>

> Nov 3 02:34:49 zeus vmunix: esp0: Unrecoverable DMA error on dma

> Nov 3 02:34:49 zeus vmunix: sd3: SCSI transport failed: reason

> 'tran_err': retrying command

> Nov 3 03:08:48 zeus vmunix: esp0: Unrecoverable DMA error on dma

> Nov 3 03:08:48 zeus vmunix: sd0: SCSI transport failed: reason

> 'tran_err': retrying command

>

> This machine has 1 SCSI processor (esp0) and 3 external SCSI hard

> disks on 1 chain, which

> by the way is less than 1 meter and is using active termination.

> I have tried to replace cables, terminator, boot using only sd0 and

> remove the other 2 drives,

> all with no effect.

>

> /dev/sd0, external

> Seagate Hawk (ST32155N) 2.1 Gigabytes

>

> /dev/sd1, external

> Seagate 32430N. Megabytes

>

> /dev/sd3, external

> Seagate Barracuda (ST32171N) 2.1 Gigabytes

>

> My questions are:

>

> 1. What do the messages from the log mean?

> 2. Are ( or could ) the error messages be related to the performance

> hit?

>

> The machine is on hardware maintenance, but our vendor thinks this is

> not a hardware issue?

Comments

Got something to say?